From: Bennett, Dan [mailto:◆◆◆◆◆◆◆◆◆]
Sent: Thursday, April 21, 2016 4:20 PM
To: paul vanevery
<pvanevery@soph-inc.com>
Subject: RE: Magnet status 1000 ton Van
Dorn
Paul,
Thanks for the report and your
quick response yesterday.
Hi Dan,
To go over my notes I am writing this down.
When I arrived at the press I found that our magnet
controller was in an alarm state. The e-stop circuit dry contact across wire
70-71 was open in our controller. This opens in any alarm
condition.
The dry contact across 70A and 71A for machine enable was
also open.
The MSD alarm light was ...
|